dnatrack is a work in progress — updates ship daily. Report a bug or request a feature →

Touch DNA collection - Performance of four different swabs

FSI Genetics, 2019

Study Design

Addressed Question

sampling efficiency of four different swab types from touch DNA samples

Activity Context

None

Category

Recovery

Specifications

Sampling

Variables of Interest

primary substratesampling individualSwap Type

Stringency of Control

Close to Realistic

Number of Individuals

4 participating sampling individuals (from 4 different laboratories in Switzerland); depositing individuals n.s.

Replicates per Individual and Condition

5 samples per substrate type

Nucleic Acid

DNA

Bodily Origin

skin (hands)

Depositor & Contact

Depositor Characteristics

N/A

Criteria for Shedder Status

N/A

Previous Activities

N/A

Contact Scenario

regular usage of samples - submission to laboratory - sampling

Primary Substrate

Primary Substrate Type

smooth and non-porous screwdriver handles, rough and non-porous leather/plastic/imitation leather steering wheels, absorbent shirt/t-shirt collars

Primary Substrate Material

CottonFabricLeatherPlastic

Deposit

regular usage

Delay

N/A

Secondary Substrate

Secondary Substrate Type

N/A

Secondary Substrate Material

N/A

Secondary Substrate Contact

N/A

Further Transfer

N/A

Sampling

Background DNA on Sampled Surface

Sampled

Sampling Time

direct/delayed

Persistence

N/A

Sampling Method

Swabbing: a - COPAN 4N6FLOQSwabs Genetics (moistened with 1 drop of water for non-absorbent surfaces), b - Puritan FAB-MINI-AP (moistened with 1 drop of water), c - Sarstedt Forensic Swabs (moistened with 3 drops of water), d - Prionics evidence collection kit (moistened with 3 drops water)

Sampling Area

area size n.s.; sampling one half with reference swab (Prionics) and the other half with one of the three "challenger swabs"

Laboratory Analysis

Extraction

PrepFiler Automated Forensic DNA Extraction Kit/Microlab STAR Line automated system

DNA Quantification

Investigator Quantiplex Hyres Quantification kit

Input for Profiling

N/A

Profiling

N/A

Reference Samples

N/A

Profile Interpretation and Mixture Analysis

N/A

RNA Data Interpretation

N/A

Results

DNA Quantity

DNA quantification values ranging from 0->7.5 ng/µl, with differences between substrates and swab types

Profile Quality

N/A

Parameter Used for Comparison

ratio of DNA quantities obtained with reference swab and challenger swab

Summary of Results

COPAN genetics swab was rated as the best swab from a practical point of view by 4 operators; On collars, the Copan swab performed significantly better than the reference swab, whereas no significant differences were observed for the other two challenger swabs; On screwdrivers, no significant differences were observed between reference and any of the challenger swabs; on steering wheels, COPAN swabs performed significantly better and Puritan swabs significantly worse than reference swabs, whereas no difference was observed between reference and Sarstedt swabs; the amounts of DNA detected were significantly dependent on swab type but not on surface type or operator; even though not statistically significant, slight differences could be observed between swab performance depending on the operator

Raised Questions

success rates of COPAN 4N6 swabs in comparison to reference Prionics swabs under "full operational conditions"

Cautionary Remarks

sampling area size n.s. (thus comparisons between substrates might be dependent not only surface type but also on sampling area)