dnatrack is a work in progress — updates ship daily. Report a bug or request a feature →

Prevalence and persistence of foreign DNA beneath fingernails.

FSI Genetics, 2012

Study Design

Addressed Question

Analysis of casework data of fingernail samples

Activity Context

CaseworkScratching

Category

Primary Deposit

Specifications

N/A

Variables of Interest

casework conditions

Stringency of Control

Reality

Number of Individuals

137 cases

Replicates per Individual and Condition

1

Nucleic Acid

DNA

Bodily Origin

fingernailspossibly bloodtrace

Depositor & Contact

Depositor Characteristics

N/A

Criteria for Shedder Status

N/A

Previous Activities

varying

Contact Scenario

analysis from 137 cases involving fingernail samples

Primary Substrate

Primary Substrate Type

body part: under fingernails

Primary Substrate Material

Skin and Nail

Deposit

case scenario (varying)

Delay

N/A

Secondary Substrate

Secondary Substrate Type

N/A

Secondary Substrate Material

N/A

Secondary Substrate Contact

N/A

Further Transfer

N/A

Sampling

Background DNA on Sampled Surface

Present

Sampling Time

delayed (varying)

Persistence

casework conditions

Sampling Method

fingernail scrapings or swabbing of fingernails clips

Sampling Area

pooling of all samples from one hand

Laboratory Analysis

Extraction

modified SDS/proteinase K lysis with organic extraction and microfiltration

DNA Quantification

QuantiBlot Human DNA quantitation kit, ABI Prism 7900 sequence detection system

Input for Profiling

1 ng (or 6 µl) DNA template, only samples >240 pg profiled

Profiling

AmpFlSTR Profiler system or AmpFlSTR Profiler Plus system, ABI Prism 377 DNA sequencer, Genescan and Genotyper software, threshold: 50 rfu, stutter peaks: -4bp, <15%

Reference Samples

taken from donors and all laboratory staff members

Profile Interpretation and Mixture Analysis

according to CFS interpretation protocols, subtraction of donor profile for mixture interpretation

RNA Data Interpretation

N/A

Results

DNA Quantity

10 % < 240 pg

Profile Quality

foreign DNA profile with <5 STR loci in 38%, >4 loci in 63%

Parameter Used for Comparison

number of foreign STR loci detected (cutoff: more or less than 5 out of 9)

Summary of Results

137 cases with 265 fingernail samples: 10 % low quality DNA, 57 % single source donor only profiles, 33% detectable foreign source with varying quality: 1-9 STR loci present, sometimes mixtures of more than one foreign source

Raised Questions

N/A

Cautionary Remarks

suitability of foreign DNA profiles for detection of foreign source not assessed (5 STR loci cut-off is arbitrary and does not represent this suitability); no differentiation between bloodstained and non-bloodstained nails