Individual shedder status and the origin of touch DNA

Forensic science international. Genetics, 2022

Study Design

Addressed Question

Examination of facial skin being a a potential source of touch DNA

Activity Context

None

Category

Primary DepositTransfer Scenario

Specifications

BG on Skin / Other Body LocationsBodily OriginDNA ProfilingIndividual Characteristics

Variables of Interest

touch DNA deposition from active and inactive handsDNA yield

Stringency of Control

Controlled

Number of Individuals

9

Replicates per Individual and Condition

1 replicate for 3 time points holding plastic tubes which active and inactive hand respectively (total=54))

Nucleic Acid

DNA

Bodily Origin

skin (hands)

Depositor & Contact

Depositor Characteristics

N/A

Criteria for Shedder Status

As described in Johannessen et al. (2021), doi: 10.1016/j.fsigen.2021.102541: DNA depositions after firmly holding a sterile plastic tube for 30s; categories of high, medium and low shedders according to the DNA strength (total RFU value) and the quality of the profile.

Previous Activities

wash both hands with soap and water for 15 seconds and let their hands air-dry, then attend 1 hour seminar with one hand (active) normal activities and one hand (inactive) not touching anything

Contact Scenario

holding plastic tube for 30s

Primary Substrate

Primary Substrate Type

plastic tube

Primary Substrate Material

Plastic

Deposit

holding for 30s, direct swabbing of 2x2cm2 squares of forehead

Delay

N/A

Secondary Substrate

Secondary Substrate Type

N/A

Secondary Substrate Material

N/A

Secondary Substrate Contact

N/A

Further Transfer

N/A

Sampling

Background DNA on Sampled Surface

Negative (Assumed)

Sampling Time

sampling within 1 hour after deposition

Persistence

< 1 hour

Sampling Method

Tubes: cotton swab (Selefa) moistened with 60 µL 0.9% NaCl, sweeping the upper tip of the cotton head in parallel movements while the swab was rotated slowly;

Sampling Area

tubes: entire surface, except for cap

Laboratory Analysis

Extraction

Chelex

DNA Quantification

RB1 qPCR assay on a LightCycler Nano instrument (Roche); specific volumes and reagents specified in chapter 2.4 "DNA quantification and STR analysis"

Input for Profiling

N/A

Profiling

PowerPlex ESX 16 Fast System (Promega Corporation), HID Veriti Thermal Cycler, ABI 3500 Genetic Analyzer (36 cm capillary array; POP4; injection parameters: 13 s/1.2 kV; analytical thresholds: blue channel 30 rfu, green 45 rfu, black (yellow) 70 rfu and red 75 rfu)

Reference Samples

yes, buccal swabs from all participants

Profile Interpretation and Mixture Analysis

≤ 3 foreign alleles counted as drop-in, foreign alleles in stutter position of donor allele removed if peak height <20% of donor allele,

RNA Data Interpretation

N/A

Results

DNA Quantity

active hand: 0.06-9.7; inactive hand: 0-3.9ng

Profile Quality

mostly complete profiles for active hand with foreign alleles present in 49% of samples; more incomplete profiles for inactive hand with foreign alleles present in 37% of samples (supplement)

Parameter Used for Comparison

number of alleles detected, percentage donor vs foreign alleles, percentage of donor vs foreign dna (TPH), total DNA amounts, statistical tests (ANOVA)

Summary of Results

strong correlation of DNA amount on hands and face indicate that source of touch DNA is not (only) from hands but from other body parts that are touched/rubbed/scatched

Raised Questions

more knowledge behind DNA shedding status required. How does it behave under certain conditions?

Cautionary Remarks

N/A