Fingerprints from Fingerprints
International Congress Series, 2003
Authors
Journal
International Congress Series
Study Design
Addressed Question
DNA profiling from fingerprints on paper
Activity Context
Category
Specifications
Variables of Interest
Stringency of Control
Number of Individuals
4
Replicates per Individual and Condition
1
Nucleic Acid
Bodily Origin
Depositor & Contact
Depositor Characteristics
2 males, 2 females
Criteria for Shedder Status
N/A
Previous Activities
N/A
Contact Scenario
deposit of fingerprint - sampling
Primary Substrate
Primary Substrate Type
standard paper sheets
Primary Substrate Material
Deposit
pressure (as if turning pages) for 1, 2, 5, 30, 50, 60s
Delay
N/A
Secondary Substrate
Secondary Substrate Type
N/A
Secondary Substrate Material
N/A
Secondary Substrate Contact
N/A
Further Transfer
N/A
Sampling
Background DNA on Sampled Surface
Sampling Time
direct
Persistence
N/A
Sampling Method
direct extraction from paper
Sampling Area
pieces of touched paper
Laboratory Analysis
Extraction
modified Invisorb Forensic kit protocol, final volume: 50 µl
DNA Quantification
Versa Fluor Fluorometer
Input for Profiling
set volume: 3 µl
Profiling
AmpFlSTR Profiler Plus PCR amplification kit 38 cycles (LCN), ABI Prism 310 Genetic Analyzer, GeneScan 3.1 software
Reference Samples
taken from depositors
Profile Interpretation and Mixture Analysis
comparison to reference profile, notion of locus drop-out as well as additional "false" alleles
RNA Data Interpretation
N/A
Results
DNA Quantity
N/A
Profile Quality
mostly complete profiles with occasional drop-in/drop-out
Parameter Used for Comparison
number of amplification, extra alleles, false alleles and allele drop-out per locus;
Summary of Results
Microscopic inspection of fingerprints on glass: Minimal incidence of nucleated cells, mostly nuclei-fee corneocytes; DNA profiles from latent prints on paper obtained from each donor, independent of handling time: mostly full or acceptable profiles with max. 23% locus dropout, 5% false alleles and 11% allele dropout
Raised Questions
N/A
Cautionary Remarks
"false alleles" not further specified (relative peak height? Possibility of contamination/transfer/background DNA?); sample size low;