Evaluating the efficiency of DNA extraction methods from different substrates.
FSI Genetics: Supplement Series, 2011
Authors
Journal
FSI Genetics: Supplement Series
Study Design
Addressed Question
comparison of two different extraction methods for low level DNA from different substrates
Activity Context
Category
Specifications
Variables of Interest
Stringency of Control
Number of Individuals
N/A
Replicates per Individual and Condition
4
Nucleic Acid
Bodily Origin
Depositor & Contact
Depositor Characteristics
N/A
Criteria for Shedder Status
N/A
Previous Activities
N/A
Contact Scenario
deposit of blood on primary substrate - sampling
Primary Substrate
Primary Substrate Type
plastic transparencies, fabric: twill woven cotton
Primary Substrate Material
Deposit
0.1, 0.5, 1, 5, 15, 30 µl blood
Delay
N/A
Secondary Substrate
Secondary Substrate Type
N/A
Secondary Substrate Material
N/A
Secondary Substrate Contact
N/A
Further Transfer
N/A
Sampling
Background DNA on Sampled Surface
Sampling Time
direct
Persistence
N/A
Sampling Method
direct extraction from substrate
Sampling Area
2x2xm^2 of deposit material + underlying transparency
Laboratory Analysis
Extraction
automated DNA IQ extraction or manual Chelex extraction
DNA Quantification
Quantifiler (Applied Biosystems)
Input for Profiling
N/A
Profiling
N/A
Reference Samples
N/A
Profile Interpretation and Mixture Analysis
N/A
RNA Data Interpretation
N/A
Results
DNA Quantity
0-800 ng
Profile Quality
N/A
Parameter Used for Comparison
extractable DNA (ng)
Summary of Results
Chelex: significantly better from cotton than from plastic, DNA IQ: minimally better from cotton than from plastic (mostly not significant); Plastic: DNA IQ performs better than Chelex, Cotton: both extraction methods perform more or less equally well; DNA yield variation higher when manual Chelex extraction method used; conclusion: extraction efficiency according to substrate type needs to be taken into account when comparing DNA yields
Raised Questions
when does the threshold effect for DNA IQ become apparent? Other differences determined by differing lab protocols?
Cautionary Remarks
more substrates in Verdon et al 2012; initial DNA deposit (i.e. without substrate) not quantified