Development of STR profiles from firearms and fired cartridge cases.
FSI Genetics, 2009
Study Design
Addressed Question
Preliminary studies on methods obtaining STR profiles from handled ammunition
Activity Context
Category
Specifications
Variables of Interest
Stringency of Control
Number of Individuals
1-3
Replicates per Individual and Condition
5
Nucleic Acid
Bodily Origin
Depositor & Contact
Depositor Characteristics
known good shedders
Criteria for Shedder Status
N/A
Previous Activities
regular activities, no handwashing or gloves in the hour prior to handling
Contact Scenario
handling ammunition for 30s (15s in each hand) - (loading into semiautomatic rifle - firing) - sampling
Primary Substrate
Primary Substrate Type
cartridges: Wolf brand caliber 7.62x39mm olive steel cartridges, Norinco caliber 7.62x39mm steel case, Remington 12 gauge 3 in. Express magnum (ribbed hull, brass head)
Primary Substrate Material
Deposit
handling 30 s (15s/hand)
Delay
N/A
Secondary Substrate
Secondary Substrate Type
N/A
Secondary Substrate Material
N/A
Secondary Substrate Contact
N/A
Further Transfer
N/A
Sampling
Background DNA on Sampled Surface
Sampling Time
direct
Persistence
firing (only Wolf brand caliber cartridges), storage of casings in plastic bags
Sampling Method
double swabbing, moistening agent: ultrapure water
Sampling Area
whole cartridge/shotshell cases
Laboratory Analysis
Extraction
DNA IQ with 20% sarkosyl, DNA IQ with standard DNA IQ lysis buffer, DNA IQ with SDS, organic extraction followed by Microcon purification
DNA Quantification
Plexor HY System, stratagene Mx3005P Real-time PCR system
Input for Profiling
set volume: 10 µl for AmpFlSTR kit, 5µl for PowerPlex 16 BIO kit
Profiling
AmpFlSTR MiniFiler kit, AmpFlSTR Identifiler Kit, 3130 Genetic Analyzer (ABI), GeneMapper ID v.3.2 software or PowerPlex 16 BIO kit, Gene Page Plus, FMBIO III+ platform, Image Analysis software v.3.0.0.79
Reference Samples
taken from all depositors
Profile Interpretation and Mixture Analysis
categorization according to profiles quality (full, strong partial (>50% expected alleles), weak partial, no profile (no alleles at all))
RNA Data Interpretation
N/A
Results
DNA Quantity
avg. 495 pg from fired and unfired Wolf brand caliber olive steel cartridges
Profile Quality
strong partial profiles or better using MiniFiler amplification, no profiles using Powerplex BIO
Parameter Used for Comparison
DNA yield (ng), profiles quality (full, strong partial (>50% expected alleles), weak partial, no profile (no alleles at all))
Summary of Results
DNA IQ extraction methods are not significantly different, whereas the organic extraction method yields significantly lower amounts of DNA; the DNA yield from fired cartridges is not significantly lower than from unfired cartridges; the average profile completeness is not significantly lower from fired than from unfired cartridges (roughly 80-85% of expected alleles) using MiniFiler; No profiles obtained using PowerPlex 16 Bio kit or Identifiler kit; No consistency observed in developing full profiles among ammunition type;
Raised Questions
N/A
Cautionary Remarks
determination method of shedder status n.s.; exact handling scenarios not always clear from methods section (e.g. subsequent handling by different participants in study testing various ammunition types not described in methods section)