Analysis of fingerprint samples, testing various conditions, for forensic DNA identification
Science and Justice, 2017
Study Design
Addressed Question
testing a sampling method for obtaining most informative profiles from items handled by multiple individuals
Activity Context
Category
Specifications
Variables of Interest
Stringency of Control
Number of Individuals
3
Replicates per Individual and Condition
6
Nucleic Acid
Bodily Origin
Depositor & Contact
Depositor Characteristics
N/A
Criteria for Shedder Status
N/A
Previous Activities
refraining from handwashing for min. 2 h prior to each experiment
Contact Scenario
consecutive holding of beer bottle by three people in a row - storage - sampling
Primary Substrate
Primary Substrate Type
amber glass bottle
Primary Substrate Material
Deposit
holding bottle with entire hand for 60s
Delay
N/A
Secondary Substrate
Secondary Substrate Type
N/A
Secondary Substrate Material
N/A
Secondary Substrate Contact
holding bottle with entire hand for 60s by second individual
Further Transfer
holding bottle with entire hand for 60s by third individual
Sampling
Background DNA on Sampled Surface
Sampling Time
delayed
Persistence
storage for 1 day at room temperature
Sampling Method
stereomicroscopic visualization, swabbing with a small portion of a sterile cotton swab, moistened with 4µl 5% Triton X-100
Sampling Area
six sections of 6x6.3cm on the bottle's trunk
Laboratory Analysis
Extraction
prepGEM Tissue Extraction Kit
DNA Quantification
Alu based real-time PCR
Input for Profiling
5 µl sample
Profiling
OCME low template protocol using the AmpFlSTR Identifiler PCR amplification kit with 31 cycles and amplification performed in triplicates; 3130xl Genetic Analyzer with reinjection of some samples according to profile appearance; GeneMapper v.4.0 software, peak amplitude threshold: 75 rfu
Reference Samples
obtained from participants
Profile Interpretation and Mixture Analysis
consensus profile obtained from all alleles detected in a minimum of two out of three amplifications; profiles suitable for database upload: 70% of known individual's alleles detected; threshold for STR profile comparison: 50% of known individual's alleles detected
RNA Data Interpretation
N/A
Results
DNA Quantity
N/A
Profile Quality
mostly 2-person mixtures
Parameter Used for Comparison
number of contributors, % of known individual's alleles detected
Summary of Results
most profiles showed 2 contributors, however, the analysis of all 6 samples per bottle led to a good estimation of the number of people that had touched the bottle (n=3); the sampling approach thus simplified mixture interpretation by reducing the number of contributors for most samples; the amount of cellular material deposited by one individual showed a higher impact on detecting that individual's DNA on the bottle than the order of touching
Raised Questions
N/A
Cautionary Remarks
bottle contact not specified except for duration, thus it cannot be determined whether all individual's touched the same parts of the bottle